RCD vs RCBO: what’s the difference?

How RCDs and RCBOs work, why it matters when something trips, and which to choose for an upgrade.

Updated 08/10/2026 · 5 min read · POLARITY.Ai

Both devices protect people from electric shock by detecting current leaking to earth and disconnecting the supply in a fraction of a second. The difference is in how much of the installation they switch off and what else they protect against.

What is an RCD?

A residual current device (RCD) compares the current flowing out on the line conductor with the current returning on neutral. If the difference exceeds its rating, usually 30mA for personal protection, it trips. In a typical “split-load” or “dual-RCD” consumer unit, one RCD protects a whole bank of circuits, with separate miniature circuit breakers (MCBs) providing overload and short-circuit protection for each circuit.

What is an RCBO?

An RCBO (residual current breaker with overcurrent protection) combines an RCD and an MCB in one device, fitted to each individual circuit. A fault on one circuit only switches off that circuit.

Side-by-side comparison

RCD + MCBsRCBO per circuit
Earth leakage protectionYes, shared across several circuitsYes, per circuit
Overload and short-circuit protectionFrom separate MCBsBuilt in
Effect of a faultSeveral circuits go off, possibly including lights and fridgeOnly the faulty circuit goes off
Nuisance trippingMore likely, as small leakages add upLess likely
CostLowerHigher, roughly £150–£400 more for a typical home

Which should you choose?

For most homes we recommend a full RCBO board: it is the most resilient option, it makes fault-finding faster and cheaper, and it avoids losing lighting and freezers when a single appliance develops a fault. A dual-RCD board is still compliant and is a reasonable budget choice. For landlords and HMOs, RCBOs reduce call-outs from tenants losing power to whole floors.

What will an EICR say?

An EICR will not code a compliant dual-RCD board as a defect. However, missing RCD protection is a common observation: for socket-outlets that may supply portable equipment outdoors it is commonly coded C2, and for other circuits it may be C3. See EICR codes explained.

Planning an upgrade? See consumer unit upgrades or read rewireable fuses vs modern consumer units.

FAQ

Frequently asked questions

Is an RCBO better than an RCD?

An RCBO gives the same shock protection but per circuit, so a fault only switches off one circuit. It is generally the better option, at a higher cost.

How often should I test my RCD?

Press the test button about every six months, or as the label on the device suggests, to make sure the mechanism works.